Specifications::
Gecor 8™
World's most
advanced system for analyzing corrosion of concrete reinforcing steel in
existing structures.

"...giving the corrosion rate most
closely matching the true values." (from the US Strategic
Highway
Research Program.) Rapid mapping capabilities for analysis
of large structures. Advanced method for more accurate
corrosion rate determination. New sensor design for analysis of wet or
submerged structures. New method for analysis of cathodic
protection systems while the system is running. Personal computer software for data
analysis and report generation. Graphical user friendly interface to
facilitate measurements.
James Instruments Gecor 8™ represents the
latest technology in steel reinforcing bar corrosion
rate determination. It combines state of the art
embedded
microprocessor systems and computerized flash technology with the
world's leading research in reinforcing bar corrosion rate analysis. The Gecor 8™ features: 1. A method for
rapidly mapping a structure's corrosion rate. An advanced modulation
confinement technique for precise corrosion rate analysis. 2. A new
corrosion rate analysis technique for use in very wet or submerged
structures. 3.
New
methodology for measurement of cathodic protection efficiency and more… The rapid mapping technique of the Gecor
8™ allows the engineer to quickly classify areas of a structure while
the unit's built-in programming can graphically analyze this data and
produce contour maps of suspected areas. And, our advanced modulation
confinement technique accurately measures the true polarization
resistance of the steel reinforcing bar. Combined with the latest advances in
interface systems and database storage technology, the Gecor 8™ is an
easy to use, reliable, automatic and
intelligent corrosion rate analysis system. A system that can save an
engineer time, money and effort in evaluating structures for subsequent
rehabilitation.
To view videos about the
Gecor 8, click on the link below.
Gecor 8™ corrosion
analysis of concrete and steel reinforcement bars Resistivity
vs Corrosion Current Density 
Contour Map
of Risk Levels 
Corrosion Rate AnalysisCorrosion of steel reinforced concrete
affects the safety and durability of concrete structures in the
following ways:
A. The steel
cross section is reduced, weakening the concrete strength.
B. The
concrete is cracked due to the increased volume in the rust.
C. The steel
to concrete bond is reduced when cracking and spalling
are initiated A true
measure of the corrosion rate is possible by the polarization resistance
technique. It has been well established by Stern and Geary that
corrosion current is linearly related to polarization resistance. This
gives a direct quantitative measurement of the amount of steel turning
into oxide at the time of measurement. By Faraday's equation, this can
be extrapolated to direct metal sectional loss. James
Instruments Gecor 8™ represents the latest technology in steel
reinforcing bar corrosion rate determination. It combines state of the
art embedded microprocessor systems and computerized flash technology
with the world’s leading research in reinforcing bar corrosion rate
analysis. The
Gecor 8™ features: 1.
A
rapid mapping technique that allows the engineer to quickly classify
areas of a structure. Both the classical corrosion potential as well as
the resistivity of the concrete can be measured. Each individual
parameter can be mapped in a multi-color contour graph. The built-in
programming also analyzes this data and the two parameters can be
combined to reliably determine areas of highest corrosion. 2.
Our
advanced modulation confinement technique precisely measures the true
polarization resistance of the steel reinforcing bar. Utilizing the
information obtained by the two reference electrodes in a feed-back
network, the unit automatically adapts the electrical field produced by
the guard ring to the conditions of the concrete. This allows the Gecor
8™ to reach a quasi steady-state condition for the 30 to 100 seconds
required for determining the polarization resistance through a
galvanostatic pulse. This advanced technology provides the most accurate
field test currently available for the determination of corrosion rate. 3.
The
Gecor 8™ also has the ability to measure corrosion rate in submerged or
very wet structures. An optional sensor has been designed to measure
corrosion rate in extremely wet environments, eliminating the need for
an external guard ring. The sensors measure polarization resistance
through the use of Feliu's formula, using three aligned field-follower
electrodes. 4. Another
optional feature is a technique to measure the cathodic protection
efficiency by analyzing the electrical impedance obtained from an
alternating current applied with modulated confinement. This method
provides a relative index of the cathodic protection performance as a
percentage. 5. PC software
assists the user to graphically interpret, collate, organize and
generate reports with the data generated from the device. It allows the
user to set up the Gecor 8™ for more rapid testing later in the field,
and will automatically link to the PC for data collection. Complete
implementation of these options provides an unprecedented system for
corrosion rate analysis of steel reinforced concrete structures. Combined with
the latest advances in interface systems and database storage
technology, Gecor 8™ is an easy to use, reliable, automatic and
intelligent corrosion rate analysis system. A system that can save an
engineer time, money and effort in evaluating corroding structures for
subsequent rehabilitation.
CORROSION RATE METER C-CS-8010 |
| Weight: | 9 lbs. (4 Kg) | Dimensions:
| 12 x 8 x 6.5 in. (300 x
200 x 360 mm)
| Batteries: | Rechargeable nickel hydride | LCD
Display: | 320 x 240
1/4 VGA |
|
| SENSOR
A C-CS-8020C / C-CS-8020A |
| Weight: | 2 lbs.
(0.9 Kg) | Dimensions: | 7 x 0.8 in. (180 Dia x 20
mm) |
|
| SENSOR
B C-CS-8030C / C-CS-8030A |
| Weight: | 0.6 lbs.
(0.3 Kg) | Dimensions: | 1.4 x 5 in.
(35
mm Dia x 130 mm) |
|
| SENSOR C C-CS-8040C / C-CS-8040A |
| Weight: | 2 lbs.
(0.9 Kg) | Dimensions: | 8.2 x 1.2 in.
(210
mm Dia x 30 mm) |
|
| SOFTWARE
C-CS-8232 |
| OP
System: | Microsoft
Windows 9 x / Me | Processor: | Pentium 166 MHz or better | Hard
Disk: | 100 Mb | RAM: | 32 Mb |
|