Home > Moisture
Testing
>


Humiditest™ Complete System
Concrete Humidity System for Testing Released Water Vapor
Before Applying a Coating, Overlay or Other Sealants

Humiditest Complete System
Humiditest Complete System


 
Questions?
Call us for more information!
Price $1,220.73


Product Code: T-HT-1000
Qty:

Product Information
 
If you are not sure on what item to buy, please see our Purchasing Notes below or contact us and we'll be glad to assist you on your order.

If you are not sure on what item to buy, please see our Purchasing Notes below or contact us and we'll be glad to assist you on your order.


Humiditest System

The tailor made solution for measuring bore hole humidity in hardened concrete.


Purchasing Notes


Applications

  • Floor Coatings

  • Concrete Overlays


Features & Benefits

  • Ensures Structure is dry before starting next construction phase.

  • Uniquely designed system to handle concrete bore hole humidity measurements.

  • Re - usable Probe for improved economics.

  • Rapid Response Time of Probe.

  • High accuracy and Long term Stability of Probe.

  • Conforms to ASTM Standard F-2170 Standard Test Method for Determining Relative Humidity in Concrete Floor Slabs.

The James Instruments Humiditest System allows the concrete practitioner to monitor and ensure that a new structure is dry enough to proceed with the next phase of construction. This is especially critical for concrete structures requiring a coating, carpeting or similar floor or covering treatment. Installing such treatments before the concrete is sufficiently dry will typically cause expensive failures in the covering treatment. The only accurate way to ensure that the concrete is sufficiently dry enough to safely avoid expensive re-work is via a bore hole humidity test system, such as the Humiditest System.

The system works by first boring a hole into the concrete and inserting a plastic tube in the hole. The plastic tube is then plugged and the system is set to stabilize and the humidity to reach equilibrium. The probe is then inserted into the plastic tube, left to stabilize for a short period of time, and then a reading is taken.

The sleeve is recommended to give readings at various depths in the concrete. As concrete moisture distribution is typically very uneven it is recommended to take readings at different depths depending on the structures exposure.


Specifications

Probe

Measurement Range
0…100% RH
Accuracy

0-90%
+/-2%RH
90-100%
+/-3%RH
Long Term Stability
( 1 Year ) 1%RH
Response Time (90% of Reading at 20° C)
15 S
Response Time
(Stabilized Hole, full reading)
30min
Temperature Range
-20°C to +60°C
Sensor Diameter
12mm
Cable Length
0.3m
Probe Length
69mm
Housing Material
ABS Plastic
Sensor Protection Membrane
Filter
Bore Hole Diameter
16mm
Measurement Depth min.
30mm


























Meter

Calculated Quantities
Dew point
Temperature
Absolute
Temperature
Wet Bulb
Temperature Resolution
0.1%RH / 0.1°C
Power Supplies
4 AA Batteries
Display
2 line LCD
Approximate Weight
300 g.











Downloadable Document



Share your knowledge of this product with other customers... Be the first to write a review

Browse for more products in the same category as this item:

Moisture