  Trident™ » Calibration Procedures
Trident™ REQUEST FOR QUOTE
  A microwave meter for rapid determination of moisture content in sand and other fine and coarse aggregrates.

Calibration Procedures

  • Dry sample in low heat using oven. It is suggested to weight sample prior to drying.
  • When sample has lost all moisture, calibration can be started.
    Weight dried sample
  • Add water by 2 percent increments.
    i.e. 4,000 grams – 2 percent water = 80 grams of water
    Turn T-90 on
  • Using up or down arrows, scroll through the menu selection until Direct mode appears on the T-90 display. (It is recommended to erase all prior data saved in the T-90. (T-90 manual page 11))
  • Take 10 readings for each percentage. Store each reading by pressing enter.
  • After T-90 has hit full saturation (direct reading 409.5 percent), uploading data to C. Software is necessary.
  • Uploading can be done by connecting the Trident™ to the P.C. using the supplied RS232 cable.
  • Use instructions in the T-90 manual pages 14-17 to successfully accomplish calibration.
  • Once analyzation has been completed with the T-90 P.C. Software, the Offset and the Gain will be displayed.
    Write down these two values.
  • Return to the T-90 and enter a user program. (T-90 manual page 7 “Change user program”)
    Once the gain and offset have been enter
  • d in the T-90, calibration has been completed.
Trident™

Technical
Specifications
Instructions
Calibration Procedures

Features & Benefits:
Fast and easy to use: Simply insert the prongs into the sand or aggregate.
Accurate.
Completely portable.
Easy to read display.
Instantaneous readings.

Downloadable Files:
Complete Data Sheets
Instructions
Calibration Procedures
 