| Digital
and manual schmidt concrete test hammers for quick and easy determination
of concrete compressive strength. Available in 'N' and 'L' type.
Frequently Asked Questions
| Q. |
Unit gives low or high readings |
| A. |
Unscrew cap on top of unit, there is a screw in the cap. Adjust the screw up or down and check reading against test anvil. |
| |
|
| Q. |
Unit will not fire when depressed |
| A. |
Make sure cap screw is in the proper position. Check to make sure trigger spring is present. Check for plunger spring in tip. |
| |
|
| Q. |
My first reading was very low, but the readings after that are consistent |
| A. |
Disengage hammer and let it sit before taking your first reading. |
| |
|
| Q. |
How many readings should I take in one particular area? |
| A. |
You should take 10 readings, if you have any large deviation, exclude them and take additional readings. |
|