For orders outside the United States and Canada please contact us and we will be happy to get you a complete quote.
If you are not sure on what item to buy, please see our Purchasing Notes below or contact us and we'll be glad to assist you on your order.
We also offer an "Add extended warranty" option to your purchased instrument! Just add it to your cart.
The instruction manual for this equipment can be found here:
Ohmcorr Manual
OhmCorr Meter™
Resistivity meter to assess corrosion currents in concrete.
-
Assesses damaging corrosion currents in concrete.
-
Economic and easy to use.
-
Direct digital readout of resistivity. Measuring from two small holes avoids the problems and errors of surface measurements.
-
Used in conjunction with CorMap™ System to produce resistivity plots.
Assesses Concrete Resistivity.
OhmCorr™ has two probes spaced 1.97" (5cm) apart which are placed in holes drilled to a depth of 3/8th" (8mm) and filled with conductive gel. The direct digital read-out of resistivity is displayed on the LCD when the control switch is activated. OhmCorr™ and CorMap™, when used together, provide an economical and sound diagnostic system of corrosion in reinforced concrete.
The electrical conductivity of concrete is an electrolytic process that takes place by the movement of ions in the cement matrix. This ionic movement will occur when contaminants such as chloride ions or carbon dioxide are introduced into the cement mortar matrix.
A highly permeable concrete will have a high conductivity and low electrical resistance. Because resistivity is proportional to current flow, the measurement of the electrical resistance of concrete provides a measure of the possible rate of corrosion. Since carbonation seriously affects surface resistance, measurement on the concrete surface should be avoided.
The James resistivity meter, OhmCorr™, has two probes spaced 5cm (1.97 inches) apart which are placed in two holes drilled to a depth of 8mm (3/8 inch) and filled with conductive gel. The concrete resistivity is displayed on an LCD when the control switch is activated.
The following table correlates a range of values vs. the possible rate of corrosion of the reinforcement bars.
RESISTIVITY LEVEL
(K OHMS CM)
|
POSSIBLE CORROSION RATE OF
REINFORCEMENT REBARS
Very High
High
Moderate to Low
Insignificant
|
The James OhmCorr™, when used in conjunction with the James CorMap™ System provides an economic and sound means of diagnoses of corrosion in reinforced concrete.
Weight complete in carrying case
|
8 lbs (4 kilos)
|
Display:
|
4-1/2” Digit in LCD
|
Resolution:
|
± 0.1K ohms cm (± 1 Digit)
|
Range:
|
0.5 - 20K ohms cm
|
Battery:
|
9 Volt
|